Technical specifications Elco systeemkabel
| Configuration | 16 x 2 x 24 AWG (0.22 mm²) acc. to Shell DEP. 32.37.20.31-GEN December 1997 | 
| Core identification code | Colored acc. to Shell DEP. 32.37.20.31-GEN December 1997 | 
| Stranding | 13 x 0.15 mm tin plated copper | 
| Number of conductors | 32, twisted in 16 pairs | 
| Insulation | PVC | 
| Diameter jacket | 1.2 mm | 
| Screening | 2 x aluminum Mylar foil 23/25 µm with drain wire 13 x 0.15 mm tin plated copper | 
| Jacket | PVC, flame retardant according BS 7655, BS 6724, IEC 60332-3 and IEC 60502 | 
| Weight | 159 kg/km | 
| Temperature | -30 ºC to +90 ºC | 
| Length | To be specified | 
| Bending radius | 6 x OD | 
| Diameter | 11.9 mm | 
| Color | Blue | 
| Loop resistance | 80 Ohm/km at 20 ºC | 
| Capacity | ± 80 nF/km | 
| Insulation resistance | >1000 Mohm × km | 
| Test voltage | 1500 VDC during 1 minute between core- core and core screen | 
| Operating voltage | 300 V | 
| RoHS | The cable is RoHS compliant according EU directive 2002/95/EG | 
Technical specifications Elco connector
| Type | Part number | 
| Empty connector body female 90 P | 00-8016-090-000-008 | 
| Cover 90 degrees | S800-0900-639 | 
| Crimp-on gold contacts | 60-8017-0323 | 
| Locking code | 4-4* | 
*Other combinations on request
Ordering data
| Type E90/32 with 1 connector of 90 degrees | Order number 89032-90-1 | 
| Type E90/32 with 2 connectors of 90 degrees | Order number 89032-90-2 |